Fully Customisable Server Rack Cooling

MAXI-COOL® cabinets can be manufactured in any RAL colour of your choice. We can also accommodate any company logo requirements taking into account your corporate brand guidelines.

Download Sheet

Maxi-Cool top mounted system

MAXI-COOL TM418

As with enterprise data centres, today’s smaller server room environments are dealing with higher and higher server rack densities. MAXI-COOL TM418 was created to provide a portable 4kW top-mounted server cooling system that was more effective than conventional environmental cooling techniques and did not require any externally mounted condensers. MAXI-COOL TM418 is an innovative server cabinet with an integrated and self contained cooler, which can be bespoke manufactured in accordance to each specific business requirement and corporate identity.

The MAXI-COOL TM418 is perfect for offices with limited space. The units can be adapted to the needs of individual servers in a modular fashion providing more efficient cooling and energy use. Multiple units can be banked together in a row creating flexible cooling solutions. The units are cooled independently using ambient air within the office and the unit itself emits less than 65db.

Performance

If servers and other networking equipment are not kept cool, they’re prone to failure and a shortened lifespan. Damage caused by heat is not always immediately evident – signs of heat damage include node crashes and hardware failures that can happen over a period of weeks or even months, leading to chronic downtime.

MAXI-COOL TM418 offers 4 kW of server cooling power, directly into the racks, but sits on top of the cabinet to maximise usable space. It reduces power consumption and running costs compared to air conditioning, and alleviates the need for a dedicated server room, meaning it can sit in an everyday office environment.

The MAXI-COOL TM418  power consumption is 9.7 Amps at full working load. A cost-effective alternative to server room air conditioning.

  • Cooling Capacity
  • Power Consumption

How It Works

Our MAXI-COOL server cabinet cooling systems are engineered to ensure all the equipment in the enclosure is precisely cooled and hotspots are eliminated. Hot air from the exhausts of the servers is drawn from the rear of the cabinet into the Maxi-Cool. Here it is cooled and then blown into the server air intakes in the front of the cabinet.

The waste heat extracted from the cabinet is expelled as warm air from the top of the MAXI-COOL® unit. The server cabinet doors are kept closed and Maxi-Cool activates when the temperature of the server intakes rise above 21 degrees Centigrade.

The cabinet is dust-free as the doors are closed and it does not need water feeds or drains. The temperature inside the cabinet is displayed on a monitor on the front of the cabinet.

Key Benefits

MAXI-COOL is a patented design and engineered and manufactured in the UK.
Reliability
MAXI-COOL® technology eliminates hot-spots and keeps servers working faster with greater reliability.
Quiet
MAXI-COOL® systems are acoustically insulated to minimise the noise from the servers. The unit itself emits less than 65db.
Quick Installation
All our MAXI-COOL® units are supplied ready for use and only take a couple of hours to install on-site.
Low Running Costs
Lower power consumption than conventional server-cooling, MAXI-COOL® reduces both your carbon footprint and your running costs.

FAQ's

MAXI-COOL® takes the form of a neat cabinet with an array of design options, it is quiet to run with no need for air-conditioning, making it an ideal solution for offices or listed buildings without dedicated server rooms.
MAXI-COOL® will work in your space if there is airflow. External cooling is not required.
MAXI-COOL® server cooling solutions are sold with 12 months parts and labour warranty. Maintenance contracts are available after the warranty period expires. Instructions for keeping the air filters clean are included.